EVALUATION OF EFFICIENCY OF ADVANCED OXIDATIVE PROCESS IN DEGRADATION OF 2-4 DICHLOROPHENOL EMPLOYING UV-C RADIATION REATOR

Léa Elias Mendes Carneiro Zaidan, Rannuzya Brandão Pinheiro, Rayany Magali da Rocha Santana, Lívia Vieira Carlini Charamba, Daniella Carla Napoleão, Valdinete Lins da Silva

Abstract


The study accomplished to analyze, identify and quantify 2,4-dichlorophenol employing high efficiency chromatography with a previously validated analytical methodology. The validation was made by using some analytical parameters: linearity, precision, accuracy, quantification limit (LOQ) and detection limit (LOD). The analytical curve was linear for the studied range of concentration (10 up to 100 mg.L-1) presenting a linear regression coefficient (R2) above 0,99. Regarding the methodology accuracy, a repeatability analysis was performed by observing a coefficient of variance (CV) below 20% for each of the concentrations used. The LOD and LOQ were adequate for the analyzed compound, showing the values of 1.42 mg.L-1 and 4.30 mg.L-1, respectively. The tests to verify the accuracy, by the recovery method provided values above 79%, thus resulting in specific, sensitive, precise, linear and accurate methodology in the studied concentration range. In the advanced oxidative process UV/H2O2, the compound was degraded to 88.04% under the following experimental conditions: [H2O2] = 1016.0 mg∙L-1 in 120 minutes. Therefore, it can be affirmed that the treatment employed can be used as an alternative for industrial effluent treatment with phenolic compounds. 


Keywords


Chromatography. 2,4-dichlorophenol. Photo-Fenton.

Full Text:

PDF

References


ANVISA - Agência Nacional de Vigilância Sanitária, RE nº 899 – Guia para validação de métodos analíticos e bioanalíticos, 12 p, Brasília, 2003.

AGHAV, R.M.; KUMAR, S.; MUKHERJEE, S.N. Artificial neural network modeling in competitive adsorption of phenol and resorcinol from water environment using some carbonaceous adsorbents. Journal of Hazardous Materials, v.188, p. 67-77, 2011.

CUNHA, F. S.; AGUIAR, A. P. Métodos para Remoção de Derivados Fenólicos de Efluentes Aquosos. Revista Virtual Química, vol. 6, n. 4, p. 844- 865, 2014.

INMETRO – Instituto Nacional de Metrologia, Normalização e Qualidade Industrial, Orientações sobre Validação de Métodos de Ensaios Químicos – Revisão: julho de 2011.

PERLATTI, B.; SILVA, M. F. G. F.; FERNANDES, J. B.; FORIM, M. R. Validation and application of HPLC–ESI-MS/MS method for the quantification of RBBR decolorization, a model for highly toxic molecules, using several fungi strains. Bioresource Technology, v.124, p.37–44, 2012.

QU, X.; TIAN, M.; LIAO, B.; CHEN, A. Enhanced electrochemical treatment of phenolic pollutants by an effective adsorption and release process. Electrochimica Acta, v. 55, n. 19, p. 5367-5374, 2010.

RIBANI, M.; BOTTOLI, C. B. G.; COLLINS, C. H.; JARDIM, I. C. S. F.; MELO, L. F. C. Validação em métodos cromatográficos e eletroforéticos. Química Nova, v. 27, n. 5, p. 771-780, 2004.

ROSA, M. D. B. da; KIST, L. T.; MACHADO, E. L. Aplicação de processo fotocatalítico homogêneo para degradação de fenóis em amostra aquosa. Revista Jovens Pesquisadores, v. 3, n. 2, p. 147-156, 2013.

SBANO, A.; FERREIRA, J. V. R.; PECKLE, B. A.; MACRAE, A.; DIREITO, I. C. N. Otimização de método cromatográfico para quantificação do herbicida ácido 2,4- diclorofenoxiacético (2,4-d). Acta Scientiae & Technicae, v. 1, n. 2, p. 1-10, 2013.

SODRÉ, F. F.; PESCARA, I. C.; MONTAGNER, C. C.; JARDIM, W. F. Assessing selected estrogens and xenoestrogens in Brazilian surface waters by liquid chromatography –tandem mass spectrometry. Microchemical Journal, v. 96, n. 1, p. 92-98, 2010.

TAUCHERT, E. Degradação de espécies organocloradas por processos oxidativos avançados envolvento o ferro metálico. Dissertação de mestrado. Curitiba, PR: UFPR, 2006.

VRSALJKO, D.; HARAMIJA, V.; HADŽI-SKERLEY, A. Determination of phenol, m-cresol and o-cresol in transformer oil by HPLC method. Electric Power Systems Research v.93, p. 24-31, 2012.

ZAIDAN L. E. M. C.; NAPOLEÃO, D. C.; GUIMARÃES, G.; BARBOSA, C. M. B. M.; BENACHOUR, M. SILVA, V. L. Validation methodology for identification and measurement of phenolic compounds in oil refinery effluent by HPLC. Brazilian Journal of Petroleum and Gas. v. 7, n. 3, p. 95-106, 2013.




DOI: https://doi.org/10.5902/2236117027766



DEAR AUTHORS,

PLEASE, CHECK CAREFULLY BEFORE YOUR SUBMISSION:

- IF ALL AUTHORS "METADATA" (ORCID, LINK TO LATTES, SHORT BIOGRAPHY, AFFILIATION) WERE ADDED,

- THE CORRECT IDIOM YOUR SECTION,

- IF THE HIGHLIGHTS WERE ADDED,

- IF THE GRAPHIC ABSTRACTS WAS ADDED,

- IF THE REVIEWERS INDICATION WAS DONE,

- IF THE REFERENCES FORMAT ARE CORRECT(ABNT)

- IF THE RESOLUTION YOUR FIGURES (600 DPI) ARE SUITABLE

*******************************

PREZADOS AUTORES,

POR FAVOR, VERIFIQUE ATENTAMENTE ANTES DA SUBMISSÃO: 
- SE OS METADADOS (ORCID, LINK PRO LATTES, CURTA BIOGRAFIA E AFILIAÇÃO) DE "TODOS" OS AUTORES FORAM ADICIONADOS, 
- IDIOMA, 
- SE OS HIGHLIHTS FORAM ADICIONADOS, 
- SE O GRAPHICAL ABSTRACT FOI ADICIONADO, 
- SE A INDICAÇÃO DOS REVISORES FOI FEITA, 
- SE O FORMATO DAS REFERÊNCIAS ESTÁ ADEQUADO (ABNT) 
- SE A RESOLUÇÃO SUAS FIGURAS (600 DPI) ESTÁ ADEQUADA.

 

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

 

**************************************************

WE ARE ON FACEBOOK! (You are our guest!)

 

Digital Object Identifier (DOI): 10.5902/22361170

Contact: reget.ufsm@gmail.com

...................................................................................


Accesses since 19/06/2012

...................................................................................